SDTM  PROTECTOR SERIES


ELECTRO STATIC DISCHARGE PROTECTION FOR COMMUNICATION INTERFACES


DATA

VOICE

AUDIO

SIGNAL

INSTRUMENTATION

PROCESS CONTROL

NETWORK INTERFACES

ETHERNET

RS-232

RS-422

RS-485
 

COMMUNICATION PORT SURGE PROTECTION   

The ZapTech SD Series static dampener devices were specifically designed to address the need to integrate ESD, EMI and transient voltage suppression in a convenient, connectorized assembly. The SD series devices can be specifically configured to virtually any physical communication interface. SD series devices are available for a wide range of technology options including choices of suppression component, impedance characteristics, clamp voltage, pin configuration, connectorization and grounding methods. The compact physical shape of the SD series enclosure allows it to be conveniently installed in-line with system interface cables.

As a significant measure to prevent disruption and electrical damage to your system, the SD series devices help extend the life of sensitive circuits at the component level while improving system reliability. Zap-Tech static dampeners are best applied as near as physically practical to the point of induction on sensitive electronic equipment, components and system ground references. SD series devices are specifically configured for installation directly in-line with the communication port on your equipment. The devices provide protection for virtually any connector interface standard versions are available for Centronics style 14 and 24 pin connectors as well as DB9, DB15 and DB25 connector interfaces.

The SD series Static Dampeners are designed to be installed in-line between the static environment and the sensitive electronic equipment. The SD device must be grounded to earth using the grounding w
ires integral to the device. 

P.O. BOX 17078
RENO, NV, USA 89511
888-727-1951  FX: 775-227-7722
WWW.Zap-Tech.Com

 

 

ZAP-TECH

 

 SD SERIES

Electrical Specifications

 

Mechanical Specifications

The Following information is needed to specify a Static Dampener device:

1. Pin configuration diagram (Number of protected circuits)
2. Protection technology desired (if known) Or:
Maximum signal
 voltage, Current and Frequency (or maximum data rate).
3. Clamp voltage desired.
4. EMI suppression impedance option.

5. Connector gender.

Model number Example:

14-A7-B-M/F
See charts below for model number logic:

1. Number of protected circuits:

 

8

14

24

36

50

Option Code

08

14

24

36

50

One circuit equals one pin. Options include from 8 to 24 protected circuits in increments of 2.

2. Protection Technology:

 

SAD

MOV

Thyristor

Mixed

Option Code

A

V

C

S

SAD = Silicon Avalanche Diode, MOV = Metal Oxide Varistor. Mixed-"S " configurations must include pin to technology assignments. "S" configuration parts are assigned a 20-XXX-XXX series part number. Contact factory for special part number assignment.

3. Clamp Voltage:

7 Volt

18 Volt

25 Volt

36 Volt

Mixed

Option Code

7

18

25

36

S

Clamp Voltages can be selected from 5 to 330 volts. Specify actual voltage. Mixed "S" voltage configurations are assigned a special 20-XXX-XXX series part number. Contact factory for special part number assignment.

4.EMI Impedance option. +/- 20%

 

170 Ohms @ 100 to 300 MHz

210 Ohms @ 100 to 300Mhz

900 Ohms @ 100 to 300Mhz

Option Code

A

B

C

5. Connector Gender Options:

 

Male to Female

Female to Male

Option Code

M/F

F/M

Special connector options are available for virtually any type of connector up to 50 circuits (pins). Connector types and cable lengths must be specified. Standard connectors are 14 pin Centronics style male to female. Special connector configurations are assigned a special 20-XXX-XXX series part number. Contact factory for special part number assignment.

 


14 Pin Series





24 Pin Series


INSTALLATION:
Zap-Tech protectors should be installed in series with the incoming communication line at the port of the equipment being protected. The protector's grounding wire must be connected to the chassis ground of the protected equipment.

IMPORTANT!
It is important that the protector and the chassis of the equipment to be protected are both properly grounded to a properly earthed electrical ground common to the equipment's chassis and to earth via a 3-prong power cord and/or a ground wire of 14 AWG or larger. Protectors should be installed at both ends of communication lines to ensure equipment protection at each end.

 

Custom variations are available including mixed or 
special voltages, different connectors or pin outs. 
Contact your supplier for details.






P.O. BOX 17078
RENO, NV, USA 89511

888-727-1951 Fx: 775-227-7722 www.zap-tech.com

All specifications are subject to change without notice.
Detailed specifications for specific versions available on request.© Copyright 2001 Zap-Tech Corporation all rights reserved.